Based on the value entered we will estimate the run time that you will have during a total power outage. Adding run time increases availability by allowing the system to operate through longer outages without shutting down.
Capacity Used. The maximum percentage of UPS capacity used to support your specified load. Nominal Output Voltage V. Nominal Input Voltage V. Cord Length 6ft 1. Includes: CD with software, Cord management straps, email privacy, firewall, Free trial of anti-virus, system recovery and online backup software, USB cable, User manual, Wall-mounting template. Audible alarms Provides notification of changing utility power and UPS power conditions.
Transformer-block spaced outlets Protect equipment with input transformer blocks without blocking access to other receptacles. Hot-swappable batteries Ensures clean, uninterrupted power to protected equipment while batteries are being replaced. Resettable circuit breakers Enables a quick recovery from overload events. Automatic self-test Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Cold-start capable Provides temporary battery power when the utility power is out. Marketing features. Dataline surge protection Provides protection of connected equipment from power surges on the data lines. Battery-protected and surge-only outlets Reserves power capacity and run time for connected equipment that require UPS battery back-up while providing surge only protection for less critical equipment.
Power conditioning Protects connected loads from surges, spikes, lightning, and other power disturbances. Safety-agency approved Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment. Product Distribution Canada, United States. Technical Specifications Print. Topology Standby. The output waveform is designed for computers and computer-related equipment.
It is not designed for use with motor-type equipment. Once On Battery, you should save your current work, power down your equipment, and turn the unit OFF. Once normal power is restored, you may turn the unit back ON and power your equipment. When the unit beeps once every second, the battery has about 2 minutes of power remaining. Immediately power down your computer and turn the unit OFF. When normal power returns, the unit will recharge the battery.
Allow the unit to charge by leaving it plugged into the wall and switched it on at least 24 hours. As a battery ages, the amount of runtime available will decrease. Battery replacement must be performed by qualified service personnel using the following procedures:. Caution : A battery can present a risk of electrical shock and high short circuit current.
The following precautions should be observed when working on batteries: Remove watches, rings, or other metal objects. Use tools with insulated handles. Disconnect all equipment plugged into the Back-UPS. Turn off the Back-UPS and disconnect it from the wall outlet. Lay the Back-UPS on a flat, stable surface with the wall mounting holes facing upward. Loosen fully, the five screws which secure the rear cover to the Back-UPS.
Lift the rear cover straight up and off of the Back-UPS. To avoid losing the screws, do not invert the rear cover. Do not touch the printed circuit board or the outlets. Disconnect the red wire from the battery terminal by grasping the black portion of the wire and pull straight back from the connector. Grasp the battery and rotate it 90 degrees stand it upright. Disconnect the black wire from the battery terminal by grasping the black portion of the wire and pull straight back from the connector.
Caution : Do not dispose of the battery in a fire. The battery may explode. Do not open or mutilate the battery. Released electrolyte is harmful to the skin and eyes. It may be toxic. Recycle or dispose of the old battery in accordance with local requirements, or return it to APC to ensure proper recycling.
Unpack and inspect the replacement battery. Ensure the replacement battery is not cracked or leaking. Forgot password? Enter your email address and check your inbox. Please check your email for further instructions. Enter a new password. ES NOTE: Small sparks may occur during battery connection. This is normal. Plug your computer, monitor, Back-UPS ES protects a single into a wall outlet; not a surge protector or and one other data-sensitive device external disk or tape line 2-wire fax, modem or power strip.
The supplied cable and software provide automatic file saving and shutdown of the operating system in the case of a sustained Battery Backup plus Surge Protection power outage. Connect the other end of the cable to the USB port on your computer. Power Switch Status Indications. See the Troubleshooting section for additional assistance.